ETIC 2230 Guía de usuario Pagina 45

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 54
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 44
OPERATION
XSLAN shdsl switch Users guide ref 9014709-01 Page 45
1 SHDSL link operation and troubleshooting
We summarize hereafter the different steps to carry-out to bring an shdsl
link into service.
1.1 Configure the products
?? Assign an IP address to each XSLAN switch
See IP protocol & routing IP protocol menu
Configure the SHDSL interfaces of each XSLAN switch
?? Configure the SHDSL port
See “Ethernet & switching” / “SHDSL port” menu
Port 1: LTU or NTU
An LTU interface must be
connected to an NTU interface.
Data rate = Select the auto option or a data rate in accordance with the
distance (see appendix 1).
Note : If the “auto” option is selected, it will cause the XSLAN to try all the
data rates. The connection delay will be longer. Moreover, the XSLAN
software will select a cautious solution. It is why the “auto” option will be
selected only if the distance is short (less than, 1 Km).
Don’t forget to SAVE each page and to REBOOT when the configuration
is carried out (click the red button “Reboot”).
1.2 Connect the line
Wire 1 and 2 of each line can be inverted.
Check the cable shield is connected to the earth.
Note : For test purposes before installation a straight RJ45 cable can be
used to simulate a line.
Vista de pagina 44
1 2 ... 40 41 42 43 44 45 46 47 48 49 50 ... 53 54

Comentarios a estos manuales

Sin comentarios